WLD sensing cable A

WLD sensing cable type A is a sensor for the detection of the presence of any conductive liquid. The liquid is detected along the entire length of the WLD sensing cable, which means that the extended area is monitored at once. The cable can be routed under the floors in datacentres or along the walls or wrapped around the pipes. Even the smallest volume of conductive liquid (water, ethylene glycol...) can trigger the alarm. The sensing cable is the essential component of the WLD system, the cable needs a WLD device or WLD relay to work properly.

WLD sensing cable is manufactured in lengths of 2m / 10 m / 50 m. Custom length is available on request.

Water Leak Detection with the sensing cable is more expensive than simple spot water detection. However, WLD provides a much faster reaction to any water in the room. Thanks to the early alert significant damages to IT or other infrastructure can be avoided. Water Leak Detection with sensing cable is recommended in IT, data centers, technology, the medical sector, or anywhere else, where any water damage would be highly expensive.

WLD sensing cable features

  • No Bend limit: WLD sensing cable Type A is not limited by any bending radius. The sensing cable can be knotted and still works properly. 
  • No Twist limit: WLD sensing cable Type A can be twisted as any other electrical cable. 
  • No Grip limit: Water detection functionality is not limited by point pressure within a reasonable range.

 WLD sensing cable Type A is not limited by any bending radius. The sensing cable can be knotted and still works properly WLD sensing cable Type A can be twisted as any other electrical cable. Water detection functionality is not limited by point pressure within a reasonable range.

 

Features: 
  • Water (or other conductive liquid) is detected along the entire length of the WLD sensing cable.
  • Early waring - even a few drops of liquid are detected
  • Long-term stable water leak detection system (no fake / false alarms)
  • WLD sensing cable can be easily combined with non-sensing prolong cable up to max total length. of 185 m (60 for NB-WLD)
  • WLD system can combine sensing and non-sensing segments of the cable to make it cost effective solution
  • WLD sensing cable is re-usable (flooded cable can be cleaned, dried & used again)
  • For use with WLD2, NB-WLD, SD-WLD and Sensor WLD Relay 1W-UNI
  • Easy & low-cost installation, Long-term reliability
  • WLD zone lenght limit (60 / 185m) is defined by used device with WLD zone input
  • Detection states: 0 = OK / 1 = Flooded / 2 = WLD cable disconnected
Applications and usage: 
  • Water Leak Detection in any environment
    • Datacenters
    • Storage room
    • Technology locations
    • Wooden constructions
    • Security systems
       
  • Can be taped on the floor, wrapped around pipes or attached to a wall.

Horizontal menu

Easy and cost-effective installation

  • The cable can be routed under the floors in datacentres or along the walls or wrapped around the pipes
  • WLD sensing cable installation can be realized even after other electrical cables are installed already.
  • No special training is required for WLD sensing cable installation.
  • Combination of sensing & non-sensing (prolong) cables according to the possible presence of water.
  • Custom solutions for every need are possible

Long-term stable detection

  • Once installed, WLD sensing cable do not generate false alarms.
  • Micro movements caused by the movement of the surrounding cables do not cause false alarms.
  • Fast reaction - even a few drops of the water will be detected.
  • Mechanically disconnected WLD sensing cable will be indicated.

WLD cable components

WLD sensing cable is supplied in lengths of 2 m, 10 m 50 m. The length of the sensing cable in 1 zone can be max. 85 m. The cable can be extended with the prolong non-sensing cable up to 185 meters/zone in total (60 m for NB-WLD). Terminator is required at the end of the zone (included in the Connection cable).

  • Connection cable - 2m (Green terminal block, 2m,  Terminator)
  • WLD Sensing cable A - 2m / 10m / 50m
  • WLD prolong cable A - 5m

 Sensing cable, Prolong cable, Connection cable, Terminator, WLD device

WLD devices

  • WLD2 (LAN & WiFi device, 4 WLD zones, Standalone Monitoring )
  • NB-WLD (NB-IoT network, 1 WLD zone, IoT Monitoring, portal required)
  • SD-WLD (LAN & WiFi device, 1 WLD zone, IoT Monitoring, portal required)
  • Sensor WLD Relay 1W-UNI (1W-UNI - RJ11 / Relay output, 1 WLD zone)

Possible installations of WLD cable

Recommended products

WLD prolong cable A

Prolong non-sensitive cable 5m for WLD type A. Can be extended to up to 100m in total.

Sensor WLD Relay 1W-UNI

A universal WLD (Water Leak Detection) sensor, with one WLD sensing cable input and 2 kind of outputs (1W-UNI sensor and relay output).

WLD2

WLD2 is a WiFi / Ethernet water leak detector with support for WWW, SNMP and PoE. To detect leaking liquids, it uses 4 sensing cables

SD-WLD

SD-WLD is a water leak detector with Ethernet and WiFi that detects the presence of water using a sensing cable.

NB-WLD

NB-WLD is a water leak detector with Narrowband IoT connectivity. It uses a very sensitive detection cable.