IT SOHO applications

How (not) to destroy a relay

A relay, being a switching element, is usually regarded as a simple component. However, it is relatively easy to destroy if it is used to switch unsuitable loads.

Horizontal menu

Changing the default configuration of Poseidon2 and Damocles2 - Disabling TCP settings

The news is that the TCP setup will be disabled in the default configuration. The default configuration is affected and this braks the backward compatibility. This will not be an issue for 99% of customers, but we need to inform you in advance. If you are updating an existing unit, this will not affect the setting. It will only be disabled on new units and by resetting to factory defaults.  You can get the latest firmware HERE.

Horizontal menu

IP Access Filtering in Poseidon2 and Damocles2 units

Ip access filter define a range of trusted IP addresses that are allowed to access the Poseidon2 and Damocles2 units over HTTP and SNMP. Each protocol has its own  table. Always only the IP addresses range is set, using the default IP address and the range around the entered value (mask), following the pattern where AND is bit multiplication. Access is granted if condition above is true.

Horizontal menu

Datacenter environment monitoring and access control systems

English
Image: 

DHZ 5/63-M-Bus

Single-phase electrocity meter 63A with M-Bus

Features: 
  • Power: 1x230V / 63A
  • Measurement: Direct
  • M-Bus interface: Yes

Horizontal menu

ED 310.I.DB HWG

ED 310.DB HWG is a static three-phase, two-tariff electricity meter for indirect measurement with 5A inputs, with M-Bus and S0 interfaces – 3x230V/400V, 5A

Features: 
  • Indirect measurment 3x230V/400V, 5A
  • M-Bus interface and S0 interface

Horizontal menu

ED 310.DB HWG

ED 310.DB HWG is a static three-phase, two-tariff electricity meter for direct measurement up to 63A, with M-Bus and S0 interfaces – 3x230V/400V, 5(63)A

Features: 
  • Power: 3x230V/400V, (5)63A
  • Measurement: Direct, max 63A
  • M-Bus interface and S0 interface

Horizontal menu

M-Count 2C

2x S0 datalogger and converter to M-Bus (2x pulse input (S0) / M-Bus output)

Features: 
  • Power Supply: M-Bus, in case of M-Bus failure from the internal lithium battery
  • Current consumption: approx. 50μA when battery operated, 1.5mA from M-Bus network
  • Battery lifetime: for consumption 0.23mAh from battery, approx. 200 days in case of M-Bus failure
  • Digital inputs: double signal inputs (S0 optional), 50Hz samping cycle (˂30 ms for S0)
  • Tariff signal: through change-over contact to TS channel or 250 VAC through ACT input
  • Interface: M-Bus according to EN1434-3 standard, 2400 baud
  • Temperature range: -20° up to +65°C
  • Mounting: Industrial DIN-rail 35mm - acc. to EN 50022 standard
  • Dimensions: 1-module size (1 - TE = 18 mm), 82x63x17.5 mm
Applications and usage: 
  • Collecting of impulses from gas-, water-, electricity- or other meters and field units with pulse output or electrical outputs of of type S0.

Horizontal menu

  • Two completely separate pulse input channels.
  • Eight memory registers for current values (high tariff HT /  low tariff NT), and historical values (dates).
  • Mounting on Industrial DIN-rail 35mm - acc. to EN 50022 standard