You are here

RS-485

  • Temperature probe for very low temperatures with a RS-485 converter in a wall-mountable box.
    Measurment OBSOLETE_Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
  • Temperature probe on a cable with a RS-485 converter in a wall-mount box. The probe (included) is on a 2m cable in a stainless-steel rod.
    Measurment OBSOLETE_Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
  • Durable industrial temperature sensor, –30°C to +70°C (–22°F to +160°F), IP65, wall mount. A Pt100 platinum temperature probe is in the tip of the protruding rod.
    Measurment OBSOLETE_Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
  • Sensor for installation to a DIN rail, designated for measuring temperature using an external Pt100 probe (not included). For use with Poseidon 2250.
    Measurment OBSOLETE_Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    Accuracy Resolution Technology Range min Range max Measure Unit
    0,03% of the range
    0.10
    Converter
    -55
    640
    Temperature
    °C
    1 NO None
  • An IP65 protected box for wall mounting, containing RS-485 converter (Temp-485-Pt100 „Head“ version). Pt100 sensor not included. new model: http://hw-group.us/sensor/temp-485-pt100-cable3
    Measurment OBSOLETE_Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    Accuracy Resolution Technology Range min Range max Measure Unit
    0,03% of the range
    0.10
    Converter
    -55
    200
    Temperature
    °C
    1 NO None
  • Sensor for installation to a DIN rail, designated for measuring temperature using 2x external Pt100 probe (not included). For use with Poseidon 2250.
    Measurment OBSOLETE_Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    Accuracy Resolution Technology Range min Range max Measure Unit
    0,03% of the range
    0.10
    Converter
    -55
    640
    Temperature
    °C
    2 NO None
  • Thermal sensor for indoor usage at RS-485 bus (communication over long distances) with a simple communication protocol. The sensor can be used separately but is designed for connection to the Poseidon measuring unit and transmit temperature over SNMP, WEB or XML.
    Measurment OBSOLETE_Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    Accuracy Resolution Range min Range max Measure Unit
    0,8
    0.10
    -10
    70
    Temperature
    °C
    1 NO None
  • Connects 4 dry contacts or 1-Wire bus RJ11 sensors to Poseidon 2250 and RS-485 (RJ45) bus.
    Measurment OBSOLETE_Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    Accuracy Resolution Technology Range min Range max Measure Unit
    1
    0.10
    Converter
    0
    1
    Switch
    switch
    6 NO None
  • Sens-485-UI connects two analog current or voltage inputs to the Poseidon unit throught RS-485 bus. DIN rail mounting, galvanic separated analog signals, both channels can be configured to measure voltage 0..15V or current 0..25mA.
    Measurment OBSOLETE_Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    Accuracy Resolution Technology Range min Range max Measure Unit
    ±0,3
    0.10
    Semiconductor
    0
    15
    Voltage
    V
    2 NO None
  • –50°C to 200°C, Pt100/A, 2m silicon cable, stainless steel tube
    Measurment OBSOLETE_Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
  • Temperature, humidity, barometric pressure and dew point temperature sensors. For indoor use. Measured values are shown on a display and transmitted to the system over RS-485. The sensors can be used alone, or with Poseidon units.
    Measurment OBSOLETE_Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    Accuracy Resolution Technology Range min Range max Measure Unit
    ±0,4
    0.10
    Semiconductor
    -30
    80
    Temperature
    °C
    4 NO None
  • Temperature and humidity sensor HTemp-485 T3419. IP40 shielding allows outdoor usage. Measured values are shown on a display and transmitted to the system over RS-485. The sensors can be therefore used alone or with Poseidon units.
    Measurment OBSOLETE_Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    Accuracy Resolution Technology Range min Range max Measure Unit
    ±0.4
    0.10
    Semiconductor
    -30
    105
    Temperature
    °C
    2
  • Temperature and humidity sensor HTemp-485 T3411. IP40 allows outdoor usage. Measured values are shown on a display and transmitted to the system over RS-485. The sensors can be therefore used alone or with Poseidon units.
    Measurment OBSOLETE_Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    Accuracy Resolution Technology Range min Range max Measure Unit
    0,4
    0.10
    Semiconductor
    -30
    80
    Temperature
    °C
    2 NO None
  • Combined temperature and humidity sensor for vertical wall mounting indoor usage. Communication over RS-485 bus with a simple communication protocol. The sensor can be used separately but it was designed to be connected with thePoseidon family units.
    Measurment OBSOLETE_Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    Accuracy Resolution Technology Range min Range max Measure Unit
    ± 0.8 °C in range from - 10°C to +80 °C
    0.10
    Semiconductor
    -10
    80
    Temperature
    °C
    2 NO None