You are here

Binary

  • SS14 is a detection device of shocks and vibrations. Is used to protect fixtures, windows, box, or any passage where is needed detect break-in attempts by vibrations or strong shocks. It 'also equipped with a separate second reed contact normally closed.
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
  • PowerEgg2 detects failures of power supply (110/230V single phase, max. load 8A) and can be also controlled with a relay. It is possible to connect PowerEgg to any device with digital inputs (DI) and/or digital outputs (DO). The controlling and controlled circuits are electrically isolated, low-voltage closing contacts are used for power detection and output control only.
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    ResolutionAccuracyTechnologyRange minRange maxUnitMeasure
    0.10
    1
    Semiconductor
    0
    1
    switch
    Switch
    1 NO None
  • AC Voltage Presence Detector Detector of 110/23V voltage failure, which can be connected directly to a wall plug. Galvanic insulated relay output (NO) can be connected to any digital input (DI) of any HW grup product. Power Detector detecs the presence of voltage which it signalizes by a relay output (galvanic insulated). Power Detector can for instance be connected to a DI of Poseidon2 3266 or Damocle2 MINI and detect the presence of charging voltage on the input of an UPS. Power Detector can...
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    1
  • Optical Smoke Detector FDR26 for smoke detection and fire alarm signalisation.
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    ResolutionRange minRange maxUnitMeasure
    0.00
    0
    1
    switch
    Switch
    NO None
  • PIR motion detector JS-20 is designed for property protection. It uses multiple signal analyzing method. For high connectivity, the product is equipped with a free pair of terminals. (GBS)
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    ResolutionAccuracyTechnologyRange minRange maxUnitMeasure
    1.00
    1
    Semiconductor
    0
    1
    switch
    Switch
    1 NO None 10mA
  • A universal water detection sensor. HWg-WLD Relay can be connected as a detector through its digital output or as a sensor via 1Wire UNI bus.
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    ResolutionTechnologyRange minUnitMeasure
    1.00
    Converter
    0
    switch
    Switch
    1 YES None 5mA
  • Detector for indication of flammable gas presence. Sensor detects all types of flammable gasses (natural gas, coalgas, propane, bottle-gas, acetylene, hydrogen, etc.) and offers 2 optional reactions according to gas concentration.
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    ResolutionRange minRange maxUnitMeasure
    0.00
    0
    1
    switch
    Switch
    NO None 100mA
  • The LD-12 flood detector is designed for detection of water leaks or detecting excessively high water level. Water detector can be connected to a dry-contact digital input (Poseidon, Damocles, I/O Controller). 12V power, transistor at the output.
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    ResolutionAccuracyTechnologyRange minRange maxUnitMeasure
    1.00
    1
    Resistor
    0
    1
    switch
    Switch
    NO None 200mA
  • Security Door contact MK4 with 3m connection wiring. Designed for door opening detection.
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    ResolutionTechnologyRange minRange maxUnitMeasure
    0.00
    Resistor
    0
    1
    switch
    Switch
    NO None
  • SL5101 calorimetric sensor detects air flow below or above a specified threshold in 1 to 10 m/s range and its output is a normally-open relay contact. The sensor needs a 24VDC power supply.
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    ResolutionAccuracyTechnologyRange minRange maxUnitMeasure
    1.00
    1
    Semiconductor
    0
    1
    switch
    Switch
    1 NO None