You are here

Binary

  • SS14 is a detection device of shocks and vibrations. Is used to protect fixtures, windows, box, or any passage where is needed detect break-in attempts by vibrations or strong shocks. It 'also equipped with a separate second reed contact normally closed.
    Measurment OBSOLETE_Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    Measure
    Vibration
    NO None
  • PowerEgg2 detects failures of a power supply (110/230V single phase, max. load 8A) and can be also controlled with a relay. It is possible to connect PowerEgg to any device with digital inputs (DI) and/or digital outputs (DO). The controlling and controlled circuits are electrically isolated, low-voltage closing contacts are used for power detection and output control only. PowerEgg is a "pass-through mains outlet" with two IEC-320 connectors – a plug (C14) at the input, and a socket (C13) at...
    Measurment OBSOLETE_Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    Measure
    Voltage
    1 NO None
  • AC Voltage Presence Detector Detector of 110/230V voltage run/failure, which can be connected directly to a wall plug. Galvanic insulated relay output (NO) can be connected to any digital input (DI) of any HW grup product. Power Detector detecs the presence of voltage which it signalizes by a relay output (galvanic insulated). Power Detector can for instance be connected to a DI of Poseidon2 3266 or Damocle2 MINI and detect the presence of charging voltage on the input of an UPS. Power Detector...
    Measurment OBSOLETE_Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    Measure
    Voltage
    1 NO None
  • Optical Smoke Detector FDR26 for smoke detection and fire alarm signalisation. The detector uses optical detector chamber for sensing of combustion products in air. It does not respond to temperature changes. The optical detector is suitable for all rooms with fluctuating temperature, like IT server rooms, telco systems, food processing, boiler stations, etc.
    Measurment OBSOLETE_Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    Accuracy Resolution Technology Range min Range max OBSOLETE_Measure Measure OBSOLETE_Unit
    1
    1.00
    Semiconductor
    0
    1
    Switch
    Smoke
    switch
    NO None
  • PIR motion detector JS-20 is designed for property protection. It uses multiple signal analyzing method. For high connectivity, the product is equipped with a free pair of terminals.
    Measurment OBSOLETE_Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    Measure
    Motion
    1 NO None
  • A universal water flood sensor detects flood occurence by soak-detecting cable. Soaking or interrupting of cable cause switching of relay contact (NO/NC) .Sensing cable detects small quantity of water or other liquid. The „ WLD sensing cable A “ is supplied in lenght from 0,4 to 85 m. It can be connected with extension cable with up to 100 m lenght. HWg-WLD Relay can be used separately with 12V power supply and relay output or as sensor with Poseidon 2 connected via 1Wire UNI bus.
    Measurment OBSOLETE_Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    Technology Range max OBSOLETE_Measure Measure OBSOLETE_Unit
    Converter
    1
    WLD
    Weather leak detection (WLD)
    WLD
    1 YES None
  • Detector for indication of flammable gas presence. Sensor detects all types of flammable gasses (natural gas, coalgas, propane, bottle-gas, acetylene, hydrogen, etc.) and offers 2 optional reactions according to gas concentration. Detector provides high stability, sensitivity and long lifetime. The gas detection can be signalized by optical, accoustic and relay output.
    Measurment OBSOLETE_Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    Resolution Range min Range max OBSOLETE_Measure OBSOLETE_Unit
    0.00
    0
    1
    Switch
    switch
    NO None
  • The LD-12 flood detector is designed for detection of water leaks or detecting excessively high water level. Water detector can be connected to a dry-contact digital input (Poseidon2, Damocles2, I/O Controller). 12V power, transistor at the output.
    Measurment OBSOLETE_Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    Measure OBSOLETE_Unit
    Weather leak detection (WLD)
    switch
    NO None
  • Security Door contact MK4 with 2m connection wiring. Designed for door opening detection.
    Measurment OBSOLETE_Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    Resolution Range min Range max Measure OBSOLETE_Unit
    0.00
    0
    1
    Switch
    switch
    NO None
  • SL5101 calorimetric sensor detects air flow below or above a specified threshold in 1 to 10 m/s range and its output is a normally-open relay contact. The sensor needs a 24VDC power supply.
    Measurment OBSOLETE_Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    Accuracy Resolution Technology Range min Range max OBSOLETE_Measure Measure OBSOLETE_Unit
    1
    1.00
    Semiconductor
    0
    1
    Switch
    Flow
    switch
    1 NO None