You are here

Binary

  • SS14 is a detection device of shocks and vibrations. Is used to protect fixtures, windows, box, or any passage where is needed detect break-in attempts by vibrations or strong shocks. It 'also equipped with a separate second reed contact normally closed.
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
  • PowerEgg2 detects failures of power supply (110/230V single phase, max. load 8A) and can be also controlled with a relay. It is possible to connect PowerEgg to any device with digital inputs (DI) and/or digital outputs (DO). The controlling and controlled circuits are electrically isolated, low-voltage closing contacts are used for power detection and output control only.
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    ResolutionAccuracyTechnologyRange minRange maxUnitMeasure
    0.10
    1
    Semiconductor
    0
    1
    switch
    Switch
    1 NO None
  • Optical Smoke Detector FDR26 for smoke detection and fire alarm signalisation.
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    ResolutionRange minRange maxUnitMeasure
    0.00
    0
    1
    switch
    Switch
    NO None
  • PIR motion detector JS-20 is designed for property protection. It uses multiple signal analyzing method. For high connectivity, the product is equipped with a free pair of terminals. (GBS)
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    ResolutionAccuracyTechnologyRange minRange maxUnitMeasure
    1.00
    1
    Semiconductor
    0
    1
    switch
    Switch
    1 NO None 10mA
  • A universal water detection sensor. HWg-WLD Relay can be connected as a detector through its digital output or as a sensor via 1Wire UNI bus.
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    ResolutionTechnologyRange minUnitMeasure
    1.00
    Converter
    0
    switch
    Switch
    1 YES None 5mA
  • Detector for indication of flammable gas presence. Sensor detects all types of flammable gasses (natural gas, coalgas, propane, bottle-gas, acetylene, hydrogen, etc.) and offers 2 optional reactions according to gas concentration.
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    ResolutionRange minRange maxUnitMeasure
    0.00
    0
    1
    switch
    Switch
    NO None 100mA
  • The LD-12 flood detector is designed for detection of water leaks or detecting excessively high water level. Water detector can be connected to a dry-contact digital input (Poseidon, Damocles, I/O Controller). 12V power, transistor at the output.
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    ResolutionAccuracyTechnologyRange minRange maxUnitMeasure
    1.00
    1
    Resistor
    0
    1
    switch
    Switch
    NO None 200mA
  • Security Door contact MK4 with 3m connection wiring. Designed for door opening detection.
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    ResolutionTechnologyRange minRange maxUnitMeasure
    0.00
    Resistor
    0
    1
    switch
    Switch
    NO None
  • SL5101 calorimetric sensor detects air flow below or above a specified threshold in 1 to 10 m/s range and its output is a normally-open relay contact. The sensor needs a 24VDC power supply.
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    ResolutionAccuracyTechnologyRange minRange maxUnitMeasure
    1.00
    1
    Semiconductor
    0
    1
    switch
    Switch
    1 NO None