You are here

1-Wire UNI

  • Pt-100 based low temperatures sensor with 1-Wire UNI output. Contains a Pt-100 temperature probe (-190 to +150°C, PTFE covered cable 2m,Pt100/B) and a 1-Wire UNI converter (Converter 2xPt100 1W-UNI). Second Pt-100 or Pt-1000 temperature probe can be connected.
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
  • Electrically isolated voltage sensor for up to 60VDC with 1Wire-UNI output. Typical applications include measuring voltage at industrial sensors (0-10V) or battery voltage. Frequently used for -48 volt power supply measurement in telecommunications (-48V standard). Voltage can be monitored over LAN (Poseidon2) or GSM (Ares).
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    ResolutionAccuracyTechnologyRange minRange maxUnitMeasure
    0.10
    2% / 25°C
    Converter
    0
    60
    V
    Voltage
    1 YES 8 5mA
  • 4 to 20 mA current loop measurement, providing power Electrically isolated 4 to 20 mA DC current sensor, 1-Wire UNI (RJ11) output. Electrically isolated, sources current to power an external 4-20mA probe. Connect an external industrial probe with a 4-20mA current loop output (“sink” type). For example a CO 2 sensor or a tank level probe.
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    1 NO 8 150mA
  • The sensor is designed for measuring of absolute value in the range 100 - 250V AC. You can connect this sensor with bus of 1-Wire UNI. Also you can mount this sensor on DIN rail. The accuracy of measuring is 5% and differentiation is 1V.
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
  • Electrically isolated current sensor for the 1Wire-UNI bus. Sensor for measuring currents in the 0–20mA or 4–20mA range. It is typically used to connect a remote industrial probe (e.g. to measure the fuel level in a tank).
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    ResolutionAccuracyTechnologyRange minRange maxUnitMeasure
    0.10
    ± 2% of the whole range
    Semiconductor
    0
    20
    mA
    Current
    1 YES 8 5mA
  • Simple light intensity sensor for indoor use. The sensor is designed for use with Poseidon and Ares devices. Connects to the 1-Wire UNI bus (RJ11).
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    ResolutionTechnologyRange minRange maxUnitMeasure
    0.10
    Semiconductor
    0
    100
    %
    Illuminance
    1 NO None 5mA
  • A universal water detection sensor. HWg-WLD Relay can be connected as a detector through its digital output or as a sensor via 1Wire UNI bus.
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    ResolutionTechnologyRange minUnitMeasure
    1.00
    Converter
    0
    switch
    Switch
    1 YES None 5mA
  • Water detection at a specific point (1D water detection). Connects to Ares or Poseidon2 using the 1-Wire UNI (RJ11) interface.
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    ResolutionAccuracyTechnologyRange minRange maxUnitMeasure
    1.00
    1
    Resistor
    0
    1
    switch
    Switch
  • Expansion module for connecting 4 dry contact inputs to Ares and Poseidon units. Connect another button, door contact, smoke detector etc. to the 1-Wire UNI bus (RJ11).
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    ResolutionAccuracyTechnologyRange minRange maxUnitMeasure
    1.00
    1
    Expander
    0
    1
    switch
    Switch
    4 YES 8 5mA
  • Double converter to connect two Pt-100 and Pt-1000 probes to 1-Wire UNI (RJ11). One or two external temperature probes can be monitored over LAN (Poseidon2) and GSM (Ares). Typical applications include measuring extreme temperatures in furnaces, coolers, engines, etc.
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
  • 30A Current probe 1W-UNI 2 is a sensor for indirect (without cutting the wire), single-phase measurement of AC current up to 30A. The split-core current transducer can be opened in order to insert a line wire. The sensor is suitable for monitoring power consumption of racks, BTS’s or server rooms.
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    1 YES 8 5mA
  • 30A Current probe 1W-UNI is a 1-Wire sensor for indirect (without cutting the wire), single-phase measurement of AC current up to 30A. The split-core current transducer can be opened in order to insert a line wire. The sensor is suitable for monitoring power consumption of racks, BTS's or server rooms.
    Measurment Sensors number Galvanic isolation Units Converter Calibrated Points Consumption
    ResolutionAccuracyRange minRange maxUnitMeasure
    0.10
    2%
    0
    30
    A
    Current
    1 YES 8 5mA