Version | Release date | File size | Download | |
---|---|---|---|---|
STE2 rev.2 / SD devices 1.3.11 | 1.3.11 | 01/12/2021 - 09:08 | 741.63 KB |
- Mod: New logo for STE2 r2
- Add: Support for low power sensors
Version | Release date | File size | Download | |
---|---|---|---|---|
STE2 rev.2 / SD devices 1.3.10 | 1.3.10 | 12/16/2020 - 11:05 | 739.83 KB |
- Add: support for up to 5 sensors for STE2 r2
- Add: 1-Wire UNI sensor support
- Add: sensor status flag in push log
- Fix: of possible memory leak when generating the certificate
- Fix: character care using escape sequences in values.xml
- Fix: edit site, freeze fields when DHCP is on / off
- Mod: increase the length of the username and password fields in smtp
- Mod: xml parser. Newly, the removal of the Esc sequence is performed directly during the parsing process and not during processing
- Mod: disable display of hidden wifi networks
- Mod: autopush method
- Mod: outputs are assigned to the AutoPush. A local change in the value of the output caused a AutoPush
- Mod: a change in the output value from the sensdesk triggered a AutoPush to let the portal know about the changes
Version | Release date | File size | Download | |
---|---|---|---|---|
STE2 rev.2 / SD devices 1.3.9 | 1.3.9 | 09/29/2020 - 16:45 | 738.5 KB |
- Fix: increased the length of the username and password field for smtp to 32 characters
- Fix: SNMP, now responds to the interaction from which the packet came
- Fix: wifi reconfiguration when changing certain wifi parameters
- Fix: display of sensor type on portal.xml page
- Mod: end of time parsing from the sensdesk via info message
Version | Release date | File size | Download | |
---|---|---|---|---|
STE2 rev.2 / SD devices 1.3.8 | 1.3.8 | 09/11/2020 - 14:57 | 740.73 KB |
- Mod: new default push period 300sec
- Mod: redesign of a uniform push time, from which the individual log entries are offset
- Fix: getting the sensor driver when sending data to the portal, so it does not interfere with the operation of the sensor
- Add: SD-4-20mA product support
- Mod: setting the datalog send flag when it is not empty after pushy
- Mod: disable datalog deletion after check pushy
- Mod: setting the logging flag for pushy only when retransmitting == 0, and pushy not triggered by a check period or event of sending the rest of the datalog
- Mod: correction of sending inaccurate values Value, min, max, hyst, ap_delta at exponent less than -1
- Mod: change of work with sensor units (UNI sensor units did not promote the system)
- Fix: freezing portal datalog, reaching beyond its poartition
- Add: import and export from SPI flash portal datalog
- Add: web push indicator
- Mod: change the way the status.xml download is suspended on the web
- Add: Calibration for SD-4-20ma (exponent and linear interpolation in 8 point)
- Mod: Tuning of SD4-20ma sensor values
- Fix: Autopush - When the sensdesk was unavailable, it pushed (and therefore logged)
- Fix: Inserting time from sensor board into retransmit, when push error was wrong device time
Version | Release date | File size | Download | |
---|---|---|---|---|
STE2 rev.2 / SD devices 1.3.7 | 1.3.7 | 08/12/2020 - 09:55 | 739.98 KB |
- Canceled Autopush setting for digital inputs on Portal page. Now depends on the "Alarm Alert" option the Inputs page
Version | Release date | File size | Download | |
---|---|---|---|---|
STE2 rev.2 / SD devices 1.3.6 | 1.3.6 | 07/30/2020 - 07:36 | 740.06 KB |
- MOD: Extend the field by e-mail to 64 characters
- Fix: LED operation inside 1-Wire connectors
- Fix: Change the time synchronization period on the Time page
- Minor modifications and improvements to the WWW
Version | Release date | File size | Download | |
---|---|---|---|---|
STE2 rev.2 / SD devices 1.3.5 | 1.3.5 | 07/15/2020 - 13:13 | 739.56 KB |
- Add: long pushlog (256kB)
- Mod: design HTML pages
- Fix: Sending values with correct exponent in HWg-Push
- Add: Outputs to the values.xml
Version | Release date | File size | Download | |
---|---|---|---|---|
STE2 rev.2 / SD devices 1.3.3 | 1.3.3 | 05/26/2020 - 10:07 | 736.91 KB |
- Fix: Flood detection on SD-WLD
- Fix: Undefined state between Normal and Flooded on SD-WLD and WLD2
- Add: Support for counters on inputs (SD-2xIN)
- Add: SD-4-20mA support
- Add: Calibration table for SD-4-20mA
- Add: Internal calibration page SD-WLD
- Add: Support for FRAM memory (counters support)
- Add: Listing of wifi modem status to setup.xml page
- Mod: HTML, JavaScripts and CSS on Alarms.xml page
- Fix. Improved link on portal.xml page, so from dynamics it refers to address according to field server address and ip port
Version | Release date | File size | Download | |
---|---|---|---|---|
STE2 rev.2 / SD devices 1.3.1 | 1.3.1 | 01/14/2020 - 08:40 | 698.05 KB |
- Fix: Sending Push message when Alarm Start or Alarm End
Version | Release date | File size | Download | |
---|---|---|---|---|
STE2 rev.2 / SD devices 1.3.0 (1) | 1.3.0 (1) | 12/10/2019 - 13:35 | 697.77 KB |
First public release