You are here

Sensors map

1-Wire products

HTemp-1-Wire Outdoor HTemp-1-Wire Outdoor HTemp-1-Wire Outdoor HTemp-1-Wire Outdoor HTemp-1Wire 3m HTemp-1Wire 3m HTemp-1Wire Rack 19 HTemp-1Wire Rack 19 HTemp-1Wire-Box2 HTemp-1Wire-Box2 Humid-1Wire (1m, 3m, 10m) Temp-1Wire (1m, 3m, 10m) Temp-1Wire 3m kalibrovaný - na vyžádání Temp-1Wire IP67 (1m, 3m, 10m) Temp-1Wire Rack 19 Temp-1Wire-Flat 3m Temp-1Wire-Outdoor
nid 8516 8516 4019 4019 4122 4122 3814 3814 3813 3813 3812 3811 7225 5615 3820 3821 3822
View
Temperature
Temperature
Range -30 - 85 °C
Accuracy
  • ± 0.8
Humidity
Humidity (relative)
Range 0 - 100 %RH
Accuracy
  • 5% RH, 2-80%RH non-condensing, 25 °C
Temperature
Temperature
Range -30 - 85 °C
Accuracy
  • ± 0.8
Humidity
Humidity (relative)
Range 0 - 100 %RH
Accuracy
  • 5% RH, 2-80%RH non-condensing, 25 °C
Temperature
Temperature
Range -30 - 85 °C
Accuracy
  • ± 0.8
Humidity
Humidity (relative)
Range 0 - 100 %RH
Accuracy
  • 5% RH, 2-80%RH non-condensing, 25 °C
Temperature
Temperature
Range -30 - 85 °C
Accuracy
  • ± 0.8
Humidity
Humidity (relative)
Range 0 - 100 %RH
Accuracy
  • 5% RH, 2-80%RH non-condensing, 25 °C
Temperature
Temperature
Range -30 - 80 °C
Accuracy
  • ± 0.8 °C in range from +0 °C to + 60 °C
  • ± 1.0 °C ( -10 °C to +70°C)
  • ± 2.0 °C (- 30 °C to + 80°C)
Humidity
Humidity (relative)
Range 0 - 100 %RH
Accuracy
  • 5% RH, 20 - 80%RH non - condensing, 25 °C
Temperature
Temperature
Range -30 - 80 °C
Accuracy
  • ± 0.8 °C in range from +0 °C to + 60 °C
  • ± 1.0 °C ( -10 °C to +70°C)
  • ± 2.0 °C (- 30 °C to + 80°C)
Humidity
Humidity (relative)
Range 0 - 100 %RH
Accuracy
  • 5% RH, 20 - 80%RH non - condensing, 25 °C
Temperature
Temperature
Range -10 - 80 °C
Accuracy
  • ± 0.8
Humidity
Humidity (relative)
Range 0 - 100 %RH
Accuracy
  • 5% RH, 2-80%RH non-condensing, 25 °C
Temperature
Temperature
Range -10 - 80 °C
Accuracy
  • ± 0.8
Humidity
Humidity (relative)
Range 0 - 100 %RH
Accuracy
  • 5% RH, 2-80%RH non-condensing, 25 °C
Temperature
Temperature
Range -10 - 80 °C
Accuracy
  • ±0,8
Humidity
Humidity (relative)
Range 0 - 100 %RH
Accuracy
  • 5% RH, 2-80%RH non-condensing, 25 °C
Temperature
Temperature
Range -10 - 80 °C
Accuracy
  • ±0,8
Humidity
Humidity (relative)
Range 0 - 100 %RH
Accuracy
  • 5% RH, 2-80%RH non-condensing, 25 °C
Humidity
Humidity (relative)
Range 0 - 100 %RH
Accuracy
  • 5% RH, 2-80%RH non-condensing, 25 °C
Temperature
Temperature
Range -10 - 80 °C
Accuracy
  • ± 0,8
Temperature
Temperature
Range -10 - 80 °C
Accuracy
  • ± 0,3
Temperature
Temperature
Range -10 - 80 °C
Accuracy
  • ± 0,8
Temperature
Temperature
Range -10 - 80 °C
Accuracy
  • ± 0.8 °C in range from - 10°C to +80 °C
  • ± 2.0 °C in whole range (- 30 °C to +125 °C)
Temperature
Temperature
Range -30 - 60 °C
Accuracy
  • ± 0.8 °C in range from - 10°C to +80 °C
  • ± 2.0 °C in whole range (- 30 °C to +125 °C)
Temperature
Temperature
Range -50 - 125 °C
Accuracy
  • ± 0.8 °C in range from - 10°C to +80 °C
  • ± 2.0 °C in whole range (- 30 °C to +125 °C)
Technology Semiconductor Semiconductor Semiconductor Semiconductor Semiconductor Semiconductor Semiconductor Semiconductor Semiconductor Semiconductor Semiconductor Semiconductor Semiconductor Semiconductor Semiconductor Semiconductor Semiconductor
OBSOLETE_1-Wire UNI NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO
Calibrated Points None None None None None None None None None None None None 3 None None None None
Consumption

1-Wire UNI products

Binary products

RS-485 products

M-BUS products

DHZ 5/63-M-Bus ED 310.DB HWG ED 310.I.DB HWG M-Count 2C
OBSOLETE_1-Wire UNI NO NO NO NO
Calibrated Points
Consumption

WLD products

PT100/1000 Probe products

Probe Pt100 TG8 Probe Pt100 TR125 2m Pt30 - 2m Pt100 version
OBSOLETE_1-Wire UNI NO NO NO
Calibrated Points None None None
Consumption